WhatsApp:
+86 18866361895
型号:YT-HC
characteristic:★ "Chassis/Medication Integrated Aluminum Alloy Chassis" is professionally designed, easy to carry, sturdy and durable, and comes with a complete set of a···
WhatsApp:+86 18866361895(Manager Xu)
WeChat:+86 17865361250(Manager Xu)
Email:yuntang@foxmail.com
Technical Parameter
Picture Introduction
characteristic:
★ "Chassis/Medication Integrated Aluminum Alloy Chassis" is professionally designed, easy to carry, sturdy and durable, and comes with a complete set of accessories and finished pharmaceuticals.
★ Microcomputer control, digital circuit, programmed design, LCD display, dual-purpose AC/DC, capable of field flow testing.
★ Resolution: 0.001, touch sensitive buttons, built-in next-generation thermal printer, capable of printing test results.
★ It can detect the content of available nitrogen, available phosphorus, available potassium, total nitrogen, total phosphorus, total potassium, organic matter, acidity and alkalinity, various trace elements such as calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, molybdenum, as well as heavy metals such as lead, chromium, cadmium, mercury, arsenic, nickel, aluminum, fluorine, titanium, selenium, etc. in fertilizers and organic fertilizers (including foliar fertilizers, water-soluble fertilizers, spray fertilizers, etc.).
★ Adopting high brightness LED light source and dual dial filter processing technology to ensure stable wavelength of the light source, silicon semiconductor is used as the signal receiving system with a lifespan of up to 100000 hours. The light source is stable, with good reproducibility and high accuracy.
The colorimetric groove adopts a single channel design, with no mechanical displacement or wear. The optical path testing positioning is precise, ensuring the accuracy of the measurement results.
★ Adopting high-precision filter technology and independent patented analysis methods to ensure that the detection results are better than the national standard requirements.
The fertilizer printing result shows a percentage content, with a testing error of less than 0.5%.
1、 Multi functional and complete testing items:
Fertilizer nutrients: ● Nitrogen, phosphorus, and potassium in elemental fertilizers; Ammonium nitrogen, nitrate nitrogen, phosphorus, potassium, and urea in compound (mixed) Hefei and urea; Organic fertilizer (foliar fertilizer) contains available nitrogen, available phosphorus, available potassium, total nitrogen, total phosphorus, total potassium, organic matter, various humic acids, etc. Scalable detection of trace elements such as calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, molybdenum, as well as various heavy metals (lead, chromium, cadmium, mercury, arsenic, nickel, aluminum, fluorine, titanium, selenium).
2、 Instrument technical specifications:
1. Power supply: AC 220 ± 22V DC 12V+5V (can be powered by a car power supply or choose the instrument's built-in lithium battery)
2. Power: ≤ 5W
3. Range and Resolution: 0.001-9999
4. Repeatability error: ≤ 0.02% (0.0002, potassium dichromate solution)
5. Instrument stability: Drift less than 0.3% within one hour (0.003, transparency measurement). After the instrument is turned on and preheated for 5 minutes, the display shows no digital drift (transparency measurement) within 30 minutes, and the digital drift within one hour does not exceed 0.3% (0.003, transparency measurement); The digital drift within three hours should not exceed 0.7% (0.007 for transparency measurement) and 0.002 (for absorbance measurement).
6. Linear error: ≤ 0.1% (0.001, copper sulfate detection)
7. Sensitivity: Red light ≥ 4.5 × 10-5 Blue light ≥ 3.17 × 10-3 Green light ≥ 2.35 × 10-3 Orange light ≥ 2.13 × 10-3
8. Wavelength range: Red light: 680 ± 2nm; Blue light: 420 ± 2nm; Green light: 510 ± 2nm; Orange light: 590 ± 4nm
9. PH value (pH): (1) Test range: 1-14 (2) Accuracy: 0.01 (3) Error: ± 0.1
10. Simultaneous, rapid, and accurate detection of nutrients such as nitrogen (N), phosphorus (P), and potassium (K) in fertilizers
11. Testing speed: Test a fertilizer sample (N, P, K) for ≤ 50 minutes (including pre-treatment time, no need for users to provide any attachments)
12. Simultaneously test 5 fertilizer samples for ≤ 2 hours (including pre-treatment time)
13. Data printing: Built in new one click thermal printer
3、 Test speed:
Can simultaneously detect 8 samples;
Test a compound fertilizer sample (N, P, K) for ≤ 50 minutes; For every additional fertilizer sample, the time increases by 20 minutes.
Test an organic fertilizer sample (N, P, K, organic matter) for ≤ 1.5 hours; Add 30 minutes for each additional sample.
4、 Test error
The individual error of fertilizer is ≤ 0.5%, and the total error of nitrogen, phosphorus, and potassium is ≤ 1%.
5、 Product Instrument Features:
Fully functional: The testing items are comprehensive both domestically and internationally (all types of drugs can be purchased).
Fully equipped, this instrument integrates medicine, apparatus, and instruments, making it easy to carry and equivalent to a small laboratory. Users only need to provide distilled water to complete all operations within the required time.
Reliable performance: The working stability is more than 8 times better than the national standard JJG179-90 index, and the repeatability reaches the level of the grating spectrophotometer index.
6、 After sales service:
The entire instrument comes with a five-year warranty, lifetime free maintenance services, free shipping of instruments, free provision of testing reagents, and free training.
Lifetime free agricultural related technical support such as soil and fertilizer!
Configuration List (Two Aluminum Alloy Boxes):
Instrument box and medicine box
Number Name Quantity Number Name Quantity
01 Host (built-in printer) 1 unit 01 Fertilizer nutrient determination medication 1 set/200 times
02 PH electrode 1 02 triangular bottle 100ml 2 pieces
03 Color dishes 4 pieces 03 Small reaction bottles 9 pieces
04 electronic balance (100g/0.01g) 1 set 04 volumetric flask 2 pieces
2 fuses 05, 1 bottle washer 05
06 Host power cord 1 piece 06 Sample spoon 1 set
07 DC 12V wire 1 piece 07 qualitative filter paper 2 boxes
08 Scale Straw 1, 5, 10ml each 1, 08 Suction Ball 1
09 instruction manual, certificate of conformity 1 set 09 small aluminum box 1
ten
10 glass reaction tubes, 30 pieces
eleven
1 centrifugal tube rack